Skip to content
Air Pollution Control+40 years of experience+3,000 installations

Tools

Decide with data, not with catalogues

Five tools to size, compare and configure your unit before you talk to us.

01 · Filter selector

Three questions and we tell you which family and model fit your process.

01What do you need to capture?
02What airflow do you need?
03Any critical requirement?

You can select more than one requirement. Leave all unchecked if you have none.

TAHI FCS

Indicative model

FCS

Compact cartridge filter

Dry filtration · 600 – 1,200 m³/h

Why

Cartridges retain dry dust; the filter medium and cleaning system are selected for the process.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

Indicative model

Consult us

Why

This combination requires engineering assessment: the exact airflow, contaminant compatibility, ATEX requirements and air recirculation conditions must be checked before selecting a unit.

Request a quote

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

Indicative model

Wet filtration

Why

Wet filtration is an option to consider without filter elements. The process, airflow and all selected requirements must be assessed to determine the appropriate equipment.

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI FCC

Indicative model

FCC

Circular cartridge filter

Dry filtration · 600 – 5,400 m³/h

Why

Cartridges retain dry dust; the filter medium and cleaning system are selected for the process.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI FCR

Indicative model

FCR

Downflow cartridge filter

Dry filtration · 2,400 – 28,000 m³/h

Why

Cartridges retain dry dust; the filter medium and cleaning system are selected for the process.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI HIW

Indicative model

HIW

Bath-type wet scrubber

Wet filtration · 1,200 – 28,000 m³/h

Why

Fibres and sticky materials can clog dry filter media. The HIW captures them through contact with water, subject to a process assessment.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI HIO Compact

Indicative model

HIO Compact

Coolant emulsion mist filter

Oil mist · 600 – 5,400 m³/h

Why

HIO Compact filters mist from emulsions (water-miscible cutting fluids).

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI FCS

Indicative model

FCS

Compact cartridge filter

Dry filtration · 600 – 1,200 m³/h

Why

Very fine, dry particulate: high-efficiency cartridges with online cleaning and saturation monitoring.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI FCC

Indicative model

FCC

Circular cartridge filter

Dry filtration · 600 – 5,400 m³/h

Why

Very fine, dry particulate: high-efficiency cartridges with online cleaning and saturation monitoring.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

TAHI FCR

Indicative model

FCR

Downflow cartridge filter

Dry filtration · 2,400 – 28,000 m³/h

Why

Very fine, dry particulate: high-efficiency cartridges with online cleaning and saturation monitoring.

View the unit

Cartridge filters can also allow air to be returned to the workshop. Suitability and the filtration required depend on the contaminant and process.

Indicative recommendation. Every installation is sized by our engineering team.

Indicative recommendation. Every installation is sized by our engineering team.

Request a quote

02 · Model comparator

Pick up to three units and compare them field by field.

Add model

You can compare up to three models at a time.

TAHI FCSFCSCompact cartridge filterView detailsTAHI FCCFCCCircular cartridge filterView detailsTAHI FCRFCRDownflow cartridge filterView detailsTAHI HIZKHIZKPre-separating cyclonesView detailsTAHI HIWVHIWVCompact wet scrubberView detailsTAHI HIWHIWBath-type wet scrubberView detailsTAHI HIZNHIZNInjection-type wet scrubberView detailsTAHI HIO CompactHIO CompactCoolant emulsion mist filterView detailsTAHI HIO MiniHIO MiniCoolant emulsion mist filterView details
FamilyDry filtrationDry filtrationDry filtrationDry filtrationWet filtrationWet filtrationWet filtrationOil mistOil mist
PrincipleCartridges, compact unitCyclonic effect + cartridgesDownflow + cartridgesCyclone (pre-separator)Cyclone + water vortexWater bathWater injection + cycloneFiltration through demistersOne demister filtration stage, with optional HEPA filtration
Airflow600 – 1,200 m³/h600 – 5,400 m³/h2,400 – 28,000 m³/h600 – 28,000 m³/h1,200 – 5,400 m³/h1,200 – 28,000 m³/h3,600 – 28,000 m³/h600 – 5,400 m³/h600 – 5,400 m³/h
Sizes1 – 21 – 64 – 12Consult us2 – 62 – 125 – 121 – 61 – 6
ConsumablesCartridgesCartridgesCartridgesNoneWater without filter elementsWater without filter elementsWater without filter elementsCleanable filtersCleanable filters
ATEXST1 optionST1 optionST1 optionST1 optionVersion and application to be confirmedVersion and application to be confirmedVersion and application to be confirmedNot available with ATEXNot available with ATEX
Best forA single workstationOne workstation / central dust extraction, depending on airflowCentralised extraction systemsRecovering materialPotentially explosive dustFibres and sticky materials / potentially explosive dustHighest demands / potentially explosive dustEmulsion (coolant) mistEmulsion (coolant) mist

03 · The process, step by step

Pick a family and watch the air travel through the unit.

Dry filtration
Contaminated airAir inlet Clean airAir outlet Collected dust
  1. 01Dust-laden air enters the filter body
  2. 02Coarse particles drop into the lower bin, depending on the model
  3. 03Fine particles are retained in the filter cartridges
  4. 04Clean air at the outlet, collected dust discharged
Wet filtration
Contaminated airAir inlet Clean airAir outlet Sludge
  1. 01Dust-laden air enters tangentially at mid-height
  2. 02Contact with water — by vortex or by injection — wets the dust
  3. 03Fine particles are trapped in the water and settle into the sludge
  4. 04Water/air separate at the top: clean air to the outside, sludge to the tank
HIO Compact — Coolant emulsion mist filter
Contaminated airAir inlet Clean airFull upper HEPA cross-section Recovered coolant

HIO Compact — Coolant emulsion mist filter

  1. 01HIO Compact: coolant emulsion mist enters the pre-separation stage
  2. 02Demisters capture droplets from the airflow
  3. 03Liquid is collected through a siphon or in a small reservoir, depending on the configuration
  4. 04Clean air exits across the full cross-section of the upper HEPA filtration stage

04 · Airflow by size and family

Twelve standard sizes, from 600 to 28,000 m³/h.

Hover a size to see which families cover it.

SizeNominal airflowDry filtrationWet filtrationOil mist
12
28,000
Standard manufactureStandard manufactureManufactured on demand
11
21,000
Standard manufactureStandard manufactureManufactured on demand
10
15,000
Standard manufactureStandard manufactureManufactured on demand
9
11,000
Standard manufactureStandard manufactureManufactured on demand
8
9,000
Standard manufactureStandard manufactureManufactured on demand
7
7,200
Standard manufactureStandard manufactureManufactured on demand
6
5,400
Standard manufactureStandard manufactureStandard manufacture
5
3,600
Standard manufactureStandard manufactureStandard manufacture
4
2,400
Standard manufactureStandard manufactureStandard manufacture
3
1,800
Standard manufactureStandard manufactureStandard manufacture
2
1,200
Standard manufactureStandard manufactureStandard manufacture
1
600
Standard manufactureManufactured on demandStandard manufacture

Standard manufactureManufactured on demand

05 · Unit configurator

Prepare a request with the model, size and options you need. Our engineers will confirm the available configuration.

Fan
Dust discharge
Construction material

Requested configuration

FCC · Size 4
ModelFCC
Nominal airflow2,400 m³/h
Size4
FanTop-mounted
Dust discharge(K) bin
Construction materialS235JR steel
ATEX—
Request a quote for this configuration

This summary records your preferences; it is not a manufacturing code or confirmation of compatibility or certification. Our engineers validate the options, fan and final reference.

Tell us your process and we’ll tell you how to filter it

In-house engineering, manufacturing in Barcelona and over 3,000 reference installations.